Skip to content
Motor-driven dosing pump

Prius D AP

Motor-driven dosing pump with PTFE diaphragm for constant dosing into high-pressure lines, up to 100 bar. The flow rate is adjusted with the stroke length knob. The high-pressure pump heads are made of AISI 316L stainless steel; a PVDF pump head is also available for the 20 bar flow rates. The pump is also available in an ATEX-certified version.

  • Up to 100 bar
  • Up to 170 l/h
  • Three-phase or single-phase
  • ATEX versions
Prius D AP dosing pump
170l/hMaximum flow rate
100barMaximum pressure
23Configurations
IP55Protection rating
The model

Prius D AP

Prius D AP dosing pump
High pressure

Prius D AP

For high-pressure constant dosing of chemicals.

  • Constant

Pump head: PVDF or AISI 316L

Power supply: three-phase 220-240 / 380-420 V 50 Hz, 220 / 380 V or 440 / 480 V 60 Hz; single-phase 220-240 V 50 Hz or 230 V 60 Hz

Operation

Dosing modes

Constant

The pump doses at a constant frequency, according to the flow rate percentage set with the knob that adjusts the stroke length of the diaphragm.

Technical data

Performance and configurations

The pump code is made up of the model name and the performance: maximum pressure in bar as two digits followed by the flow rate in l/h (Prius D AP 5017 = 50 bar, 17 l/h). Performance depends on the working back pressure, the number of strokes per minute and the characteristics of the chemical; with viscous products a lower number of strokes per minute is recommended.

Manual air bleed

Manual air bleed, suitable for most chemicals. LM AP, MM AP, SM AP and TM AP high-pressure pump heads in AISI 316L, NM AP in PVDF.

CodeMax pressure (bar)Max flow rate (l/h)Strokes / minuteMotor (kW)Pump headStroke (mm)
Prius D AP 1000410041750.37LM AP1.5
Prius D AP 100021002940.37LM AP1.5
Prius D AP 1001.51001.5700.37LM AP1.5
Prius D AP 501750171750.37MM AP2
Prius D AP 5009509940.37MM AP2
Prius D AP 5005505700.37MM AP2
Prius D AP 502.5502.5350.37MM AP2
Prius D AP 302830281750.37MM AP2
Prius D AP 30143014940.37MM AP2
Prius D AP 30103010700.37MM AP2
Prius D AP 3005305350.37MM AP2
Prius D AP 307630761750.37SM AP4
Prius D AP 30413041940.37SM AP4
Prius D AP 30303030700.37SM AP4
Prius D AP 30153015350.37SM AP4
Prius D AP 20170201701750.37TM AP6
Prius D AP 20912091940.37TM AP6
Prius D AP 20682068700.37TM AP6
Prius D AP 20342034350.37TM AP6
Prius D AP 203020301750.37NM AP2
Prius D AP 20162016940.37NM AP2
Prius D AP 20122012700.37NM AP2
Prius D AP 2006206350.37NM AP2

Motor ratings refer to three-phase 50 Hz motors; with a single-phase motor some models are fitted with a motor of different power.

Technical specifications

SpecificationValue
Power supplyThree-phase 220-240 / 380-420 V 50 Hz, 220 / 380 V or 440 / 480 V 60 Hz; single-phase 220-240 V 50 Hz or 230 V 60 Hz
Ambient temperature−10 – 40 °C
Chemical temperature with PVDF pump head−10 – 65 °C
Chemical temperature with AISI 316L pump head−10 – 90 °C
Noise level78 dB(A) ± 5 dB
Maximum suction lift3 m
Gearbox oil0.3 l
Motor0.37 kW three-phase; 0.37 kW or 0.55 kW single-phase

The maximum chemical temperatures may be exceeded for a limited time, no longer than 15 minutes, during sterilisation or washing with hot water.

Hydraulic connections

Pump headMaterialConnection
LM APAISI 316LR 3/8″
MM APAISI 316LR 1/2″
SM APAISI 316LR 1/2″
TM APAISI 316LR 3/4″
NM APPVDF8 × 10 PVDF or 8 × 12 PVC tube

ATEX versions

CategoryMarkingConstruction
Category 2, gas (zone 1)II 2G Ex h IIC T3 GbAISI 316L
Category 2, dust (zone 21)II 2D Ex h IIIC T120 °C DbAISI 316L

The ATEX versions are designed in accordance with Directive 2014/34/EU and can be used in zones classified according to Directive 1999/92/EC. Their performance and motor ratings differ in part from those listed above and are provided on request.

Compatible lubricating oils

BrandOil
MobilMobilgear 632
ShellOmala Oil 320
BPEnergol GR-XP 320
IPMellana Oil 320
EssoSpartan EP 320
AgipBlasia 320

The pump is supplied with the oil already filled; the level is checked through the sight glass and the oil must be changed at least once a year.

Construction

  • Aluminium housing with epoxy coating
  • IP55 protection rating (IP65 optional)
  • PTFE diaphragm

Supplied with

  • Gearbox oil, already filled
  • Blind plug for transport

Pump head materials

Pump head in PVDF

PVDF

Suitable for most acids, for peroxides and for sodium hypochlorite (chlorine).

Pump head in AISI 316L

AISI 316L

Suitable for peracetic acid and sodium hydroxide.

Learn more: chemical compatibility of materials →

Technical support

Troubleshooting and error messages

The most frequent causes of malfunction and the corrective actions to check before contacting technical support.

Learn more: the pump does not prime and does not dose →

If the pump…

Insufficient or no flow rate
  • Air in the pump head or in the suction tubePrime the pump until all the air has been expelled.
  • Suction valve or tube obstructed or not sealingClean or replace the suction valve; replace the tube.
  • Foot filter cloggedClean the filter.
  • Excessive suction lift relative to the tankReduce the suction lift.
  • High-viscosity liquidUse a larger-diameter suction tube.
Overheating of the motor and pump head
  • Insufficient oil levelTop up the oil: the pump must never run without lubricant.
  • Operating pressure above the rated valueInstall a pressure relief valve.
  • Delivery line obstructed or blockedClear the delivery tube.
  • Incorrect electrical connectionsReconnect the pump according to the instructions in the manual.
Liquid leaking from the pump head
  • Ruptured diaphragmContact our technical support service to have the diaphragm replaced.

First start-up

Start the pump with the stroke length set to 20% and minimum back pressure; after about 5 minutes increase it gradually. If the pressure exceeds the rated value, stop the motor immediately.

Oil

Check the level using the dedicated indicator and never run the pump without oil; change it every 8,000 – 10,000 operating hours and in any case at least once a year.

Periodic checks

Every three months check bolts and seals; once a year check that flow rate, pressure and power match the rating plate data. With abrasive or corrosive chemicals, shorten the intervals.

If the problem persists, contact us. Before sending the pump for servicing, empty the pump head of chemical and dry it.

Summary

Main features

Mechanical flow rate adjustment

The knob reduces the stroke length of the diaphragm, i.e. the volume of each injection and, consequently, the maximum flow rate. This offers two advantages:
Linear dosing: a high number of small-volume injections promotes mixing of the chemical into the water flow and avoids concentration peaks.
Accuracy at low dosing rates: with a 10 l/h pump required to dose 1 l/h, reducing the stroke length to 50% brings the maximum flow rate down to 5 l/h and doubles the injection frequency. Particularly suitable in combination with the pulse-output water meter.

Versatile mounting

Horizontal installation, or vertical installation by means of a dedicated bracket.

Technical advice

Tell us about your application: our technical staff will recommend the most suitable model, configuration and accessories.

Contact

Tell us about your plant

Call or write to us: a technician will reply with a tailored proposal of controllers, pumps, probes and accessories.

What do you need?
Please enter your name.
Please enter a valid email address.
Please enter your message.

Describe your plant: type, water volume or flow rate, parameters to be controlled.

You must accept the privacy notice to continue.